Answer:
C. Conduction
Explanation:
Conduction is heat transfer through stationary matter by physical contact.
The Werner family is very cost-conscious. They want a system with low maintenance costs. Which system should they avoid?
A. Boiler
B. Heat pump
C. Baseboard
D. Radiant ceiling
Where the Werner family is very cost-conscious and they want a system with low maintenance costs, the system they should avoid is: "Boiler System" (Option A)
What is a boiler system?Because the Werners want a system with low maintenance costs, a boiler system may not be the best option.
Regular maintenance and service are required for boiler systems, such as checking and cleaning the burners, replacing filters, and flushing the system to remove buildup. They also necessitate more frequent repairs as parts wear out, resulting in higher maintenance costs.
As a result, the Werners should avoid using a boiler system and instead consider alternatives such as a heat pump or a radiant ceiling system, which are known for their low maintenance costs and dependability.
Learn more about boilers:
https://brainly.com/question/14241641
#SPJ1
10. Technician A says to make the finish cut at the slowest speed when machining brake drums. Technician B says that the drum should not exceed its discard diameter. Who is correct?
When milling, technician A advises using the slowest speed for the end cut. According to technician B, the drum shouldn't be larger than its disposal diameter.
What is the process of milling?
Cleaning, grading, breaking down, sizing, separating, or classifying dry bulk materials are all included in the term "milling process." The mill is used in the actual milling process to grind, cut, or crush solid bulk materials into smaller bits. Ingilling is the practise of using a specialised machine to grind, cut, press, or crush a material. Cutting away material with a spinning cutter that has several teeth is called milling.
Know more about disposal Visit:
https://brainly.com/question/14732695
#SPJ1
An air-conditioning system's automatic controller might directly control the
A. conversion of pneumatic energy to hydraulic signal pressure.
B. thermostat's setpoint temperature.
C. motor of a large condenser fan.
D. sensitivity of the ladder logic.
Note that an air-conditioning system's automatic controller might directly control the: "motor of a large condenser fan" (Option C)
What is a Condenser Fan?A condenser fan is a type of fan that is found near the condenser, as the name implies. Its purpose is to remove heat from the refrigerant inside the hollow passages of the condenser. When your air conditioner is turned on, the refrigerant at the evaporator coil absorbs heat from the inside of your home.
The automatic controller of an air-conditioning system is a device that controls the operation of the air-conditioning system. It has the ability to directly control the motor of the large condenser fan. This motor is in charge of blowing air over the condenser coils, which aids in the dissipation of heat absorbed by the refrigerant.
Learn more about air conditioning:
https://brainly.com/question/29648889?
#SPJ1
Which statement describes what occurs in both animal and plant cells? Responses A Nitrogen is used for respiration and carbon dioxide is a waste product.Nitrogen is used for respiration and carbon dioxide is a waste product. B Nitrogen is used for respiration and oxygen is a waste product.Nitrogen is used for respiration and oxygen is a waste product. C Carbon dioxide is needed for respiration and oxygen is a waste product.Carbon dioxide is needed for respiration and oxygen is a waste product. D Oxygen is used for respiration and carbon dioxide is a waste product.
Answer:D. Oxygen is used for respiration and carbon dioxide is a waste product.
Both animal and plant cells use oxygen for respiration, which is the process of converting nutrients into energy. During respiration, oxygen is consumed and carbon dioxide is produced as a waste product. In plant cells, photosynthesis also occurs, which is the process of using sunlight, carbon dioxide, and water to create glucose and oxygen. But respiration, consuming oxygen and producing carbon dioxide, is a common process that happens in both animal and plant cells.
Explanation:
Anna is very picky about the temperature in her home and wants full control of air flow and heat/cooling. She should install a system that includes
A. floating control.
B. an automated mixing chamber.
C. two-position control.
D. a low differential.
Where Anna is very picky about the temperature in her home and wants full control of airflow and heat/cooling. She should install a system that includes: "a low differential" (Option D)
What is a Low Differential?The temperature differential in HVAC terms refers to the temperature difference between the inside and outside areas of the house.
The thermostat has an adjustable temperature differential setting that determines how frequently your system cycles. The lower the differential setting, the more frequently your system will cycle and the tighter the temperature will be maintained.
Learn more about Differential Heating:
https://brainly.com/question/28033741
#SPJ1
The amount of time it takes for one Btu to flow across one square foot of surface when there's a one-degree difference in temperature from one side of the material to the other is known as
A. internal heat gain.
B. thermal capacity.
C. the R-value.
D. the insulating factor.
Where the amount of time it takes for one BTU to flow across one square foot of surface when there's a one-degree difference in temperature from one side of the material to the other is known as: ".the R-value." (Option C)
What is a BTU?The British thermal unit is a heat unit defined as the amount of heat needed to raise the temperature of one pound of water by one degree Fahrenheit. It is also one of the customary units used in the United States.
Note that the R-value is a measure of thermal resistance that indicates how long it takes for one Btu to flow across one square foot of surface when there is a one-degree temperature difference from one side of the material to the other. It is the inverse of the U-value (thermal transmittance), which is used to calculate heat loss.
Learn more about BTU:
https://brainly.com/question/7411071
#SPJ1
Two electricians are discussing outdoor receptacles. Electrician A says that one receptacle is required in the front and back of all dwelling types. Electrician B says the plans call for mounting the rear outdoor receptacle outlet six feet, six inches from the outside edge of a deck. Which of the following statements is correct?
A. Both electricians are correct.
B. Neither electrician is correct.
C. Only Electrician B is correct.
D. Only Electrician A is correct.
Where two electricians are discussing outdoor receptacles. Electrician A says that one receptacle is required in the front and back of all dwelling types. Electrician B says the plans call for mounting the rear outdoor receptacle outlet six feet, six inches from the outside edge of a deck, the electrician that is correct is "Both" (Option A).
What is the rationale for the above response?The National Electric Code (NEC) requires that all dwelling types have at least one receptacle in the front and back.
Furthermore, the NEC requires outdoor receptacles to be at least six feet, six inches from the outside edge of a deck. As a result, both electricians are correct in their assertions.
Learn more about receptacles:
https://brainly.com/question/28215225
#SPJ1
Which would constitute the last step in a central-fan cooling control sequence?
A. During the cooling season, when the home's air temperature rises above a predefined setpoint, the room thermostat calls for cooling and energizes the refrigeration control circuit
B. Cool air from the fan system is delivered through ductwork to occupied spaces within the home. When the space temperature within the fan unit drops below the room temperature setpoint, the refrigeration unit shuts down.
C. When the air temperature within the fan unit drops below the setpoint of an internal controller, the blower motor is energized.
D. The blower continues to operate until the temperature within the fan unit rises above the setpoint of the internal controller, at which time the blower shuts off.
Answer:D. The blower continues to operate until the temperature within the fan unit rises above the setpoint of the internal controller, at which time the blower shuts off.
Explanation: i big brained thats y
1. Roy intends to use a seam that is used for joining metals where extra stiffness is needed,such as roofs, air housing, ducts, and so forth. What would you suggest to Roy to use?
A. cap strip B. counter lap
C. lap seam D. standing
2. What word refers to a full-sized drawing of the various surface of an object stretched out on a flat surface?
A. development B. hem
C. pattern D. seam
3. Which of the following words is the most commonly used to reinforce an edge, hide burrs and rough edges, and improve appearance?
A. hem B. seam
C. standing seam D. wired seam
1) Where Roy intends to use a seam that is used for joining metals where extra stiffness is needed, such as roofs, air housing, ducts, and so forth, the best suggestion to Roy is for him to use: "standing seam (Option D)
2) Note that the word refers to a full-sized drawing of the various surface of an object stretched out on a flat surface is; "A development" (Option A)
3) The words the most commonly used to reinforce an edge, hide burrs and rough edges, and improve the appearance is: Hem (Option A)
What is a standing seam?A standing seam is a type of seam formed by turning up the edges of two adjacent sheets of metal roofing material and then folding or interlocking them in a variety of ways.
Roy can use a standing seam, which is a type of seam used for joining metals that require extra stiffness, such as roofs, air housing, and ducts.
Learn more about seams:
https://brainly.com/question/20381434
#SPJ1
Martavis is installing a smart thermostat into a home built in the 1950s. The home still has the original steam boiler as its heat source and currently is set using the original dial thermostat. After connecting all of the old wires to the smart thermostat, Martavis notices that it doesn't turn on. What is the most likely issue with the installation?
A. The new smart thermostat is defective.
B. There's no C wire since the original thermostat is older.
C. There's no R wire since the home doesn't have a central air system.
D. The new smart thermostat isn't compatible with this type of boiler.
Where Martavis is installing a smart thermostat into a home built in the 1950s. The home still has the original steam boiler as its heat source and currently is set using the original dial thermostat. After connecting all of the old wires to the smart thermostat, Martavis notices that it doesn't turn on. Note that he most likely issue with the installation is: "There's no C wire since the original thermostat is older." (Option B)
What is a Smart Thermostat?Smart thermostats are Wi-Fi thermostats that can be used with home automation to control the heating, ventilation, and air conditioning in a home.
The most likely problem with installing a smart thermostat in a 1950s home is that the original thermostat does not have a "C" wire, which is typically used to provide a common power source to the thermostat. Smart thermostats require a "C" wire for power and will not function if the home does not have one.
Learn more about Smart Thermostat:
https://brainly.com/question/30112238
#SPJ1
Eve's contractor recommended she not install baseboard heating. In which scenario would it be disadvantageous to install a baseboard heating system?
A. Where electricity is generated from a gas-fired plant.
B. Where there is high room air circulation.
C. Where there are low ceiling heights.
D. Where the TD is zero
Note that where Eve's contractor recommended she not install baseboard heating. The scenario where would it be disadvantageous to install a baseboard heating system is: "Where there are low ceiling heights." (Option C)
What is a Baseboard Heating?The term "baseboard heat" refers to the position of the heater along the bottom of the wall. The idea behind this placement is that heat naturally rises, so by beginning along the floor, the heat gradually rises into the area between the floor and ceiling where you spend the majority of your time.
Baseboard heating systems, which are typically installed along the base of the walls, heat a room by relying on the natural rise of warm air. If the ceiling height is low, warm air may not have enough space to rise, resulting in poor heating performance and decreased efficiency.
Learn more about Baseboard Heating:
https://brainly.com/question/5248745
#SPJ1